Gait speed assessment in confined spaces: Development of a novel automated 4‐m static‐start test to measure dynamic‐start gait speed
Yong‐Hao Pua · Ross A. Clark · Laura Tay · Yee Sien Ng · Juliana Poh · Salma Bte Md Ibrahim · Wei-Kuen Cheong · Hong‐Han Tan · Julian Thumboo
Geriatrics and Gerontology International
Abstract
OBJECTIVES: To promote standardization and feasible measurements of gait speed across the field, we developed a device that used light detection and ranging (LiDAR) technology to measure gait speed from a standing-start testing procedure conducted on a 4-m total walkway. We compared this automated (LiDAR-based) standing-start 4-m gait speed test (AS-4MG) with automated and manual (stopwatch-based) dynamic-start 4-m gait speed tests (AD-4MG and MD-4MG, respectively) on between-method agreement, measurement repeatability, and predictive validity with functional outcomes.
METHODS: A sample of 48 community-dwelling adults (mean [SD], 69 [9] years) participated in this method comparison study. Participants completed a survey and a physical function assessment, from which self-reported stair difficulty, handgrip strength, sit-to-stand performance, and gait speed (AS-, AD-, and MD-4MG) were measured.
RESULTS: Mean AS-4MG, AD-4MG, and MD-4MG were 1.12, 1.13, and 1.14 m/s, respectively, with a strong correlation (r = 0.94) and no systematic bias observed between AS-4MG and the referent AD-4MG. In the analyses of repeated gait measurements, coefficients of repeatability were <0.20 m/s for the automated tests (0.16 and 0.18 m/s for AS-4MG and AD-4MG, respectively) but not for MD-4MG (0.22 m/s). Correlations between gait speed and functional measures ranged between 0.44 and 0.68 (Ps < 0.01). Correlations for the automated tests were comparable, while AS-4MG correlations tended to exceed MD-4MG correlations.
CONCLUSIONS: In community-dwelling adults, the AS-4MG test was unbiased when compared with the AD-4MG, encompassing a 9-m walkway, with both tests showing equivalence of measurement repeatability and predictive validity. The AS-4MG potentially allows gait measurements in confined spaces (e.g., doctor's office) where the gait speed test was previously unfeasible. Geriatr Gerontol Int 2025; 25: 449-453.
Abstract source ↗Cite this publication
Download Plain textCitation fields reflect the indexed metadata. Check author formatting and publication details against the source before submission.
Explore related topics
Suggested by subject matter. These links do not imply that a tool was used or validated in this study.
Record provenance
Indexed record: W4406598648. Matched to Scopus author 55279534900.
Scopus record ↗Metadata retrieved 2026-09-20. Topic labels are navigation aids derived from title and abstract text.