Abstract

OBJECTIVES: To provide an easy-to-use measure, as existing objective assessments for freezing of gait (FOG) severity may be unwieldy for routine clinical practice, this study explored time taken to complete the recently validated FOG severity tool and its components.

DESIGN: A cross-sectional study.

SETTING: Outpatient clinics of a tertiary hospital.

PARTICIPANTS: People with Parkinson disease who could independently ambulate 8-meters, understand instructions, and without co-morbidities affecting gait were consecutively recruited. Thirty-five participants were included (82.9% [n=29] male; median [IQR]: age of 73.0 [11.0] years and disease duration of 4.0 [4.5] years).

INTERVENTIONS: Not applicable.

MAIN OUTCOME MEASURES: Participants were assessed with the FOG severity tool in a test-retest design, with time taken for each component recorded using a stopwatch during video-analysis. Validity of total FOG severity tool time, time taken to complete its turning and narrow-space components (i.e., time to navigate [TTN]), and an adjusted TTN were examined through correlations with validated FOG severity outcomes. To facilitate clinical interpretation, the TTN cut-off was determined using scatterplot smoothing regression, whereas minimal important change was calculated using predictive modeling.

RESULTS: The FOG severity tool time, TTN, and adjusted TTN similarly demonstrated moderate correlations with the FOG questionnaire and percentage-FOG, and very high correlations with FOG severity tool-revised. The TTN was nonlinearly related to FOG severity, with a positive relationship observed in the first 300 seconds and plateauing after. minimal important change for TTN was 15.4 seconds reduction in timing (95% CI, 3.2-28.7).

CONCLUSIONS: The TTN is a feasible, interpretable, and valid test of FOG severity. In busy clinical settings, TTN can provide a viable alternative when use of existing objective FOG measures is (often) unfeasible.

Abstract source ↗
Cite this publicationDownload Plain text

Citation fields reflect the indexed metadata. Check author formatting and publication details against the source before submission.

Explore related topics

Suggested by subject matter. These links do not imply that a tool was used or validated in this study.

Record provenance

Indexed record: W4402611745. Matched to Scopus author 55279534900.

Scopus record ↗

Metadata retrieved 2026-09-20. Topic labels are navigation aids derived from title and abstract text.

← All publications