Effect of Context Specificity on Response to the Shortened WOMAC Function Scale in Patients Undergoing Total Knee Arthroplasty
Yong‐Hao Pua · Samantha Shi-Man Koh · Berend Terluin · Ee-Lin Woon · Eleanor Shu-Xian Chew · Seng-Jin Yeo · Jerry Yongqiang Chen · Lincoln Ming Han Liow · Ross A. Clark · Julian Thumboo
Archives of Physical Medicine and Rehabilitation
Abstract
OBJECTIVE: To determine, in patients undergoing total knee arthroplasty (TKA), whether increasing context specificity of selected items of the shortened version of the Western Ontario and McMaster Universities Osteoarthritis Index function (WOMAC-F) scale (ShortMAC-F) (1) enhanced the convergent validity of the ShortMAC-F with performance-based mobility measures (ii) affected mean scale score, structural validity, reliability, and interpretability.
DESIGN: Secondary analysis of randomized clinical trial data.
SETTING: A tertiary teaching hospital.
PARTICIPANTS: Patients undergoing TKA (N=114).
INTERVENTIONS: Not applicable.
MAIN OUTCOME MEASURES: The ShortMAC-F was modified by specifying the "ascending stairs" and "rising from sitting" items to enquire about difficulty in performing the tasks without reliance on compensatory strategies, whereas the modified "level walking" item enquired about difficulty in walking 400 m. Before and 12 weeks after TKA, patients completed the WOMAC-F questionnaire, modified ShortMAC-F questionnaire, knee pain scale questionnaire, sit-to-stand test, fast gait speed test, and stair climb test. Interpretability was evaluated by calculating anchor-based substantial clinical benefit estimates.
RESULTS: The modified ShortMAC-F correlated significantly more strongly than ShortMAC-F or WOMAC-F with pooled performance measures (differences in correlation values, 0.12-0.14). Increasing item context specificity of the ShortMAC-F did not influence its psychometric properties of unidimensionality (comparative fit and Tucker-Lewis indices, >0.95; root mean square error of approximation, 0.05-0.08), reliability (Cronbach's α, 0.75-0.83), correlation with pain intensity (correlation values, 0.48-0.52), and substantial clinical benefit estimates (16 percentage points); however, it resulted in lower mean score (4.5-4.8 points lower).
CONCLUSIONS: The modified ShortMAC-F showed sufficient measurement properties for clinical application, and it seemed more adept than WOMAC-F at correlating with performance-based measures in TKA.
Abstract source ↗Cite this publication
Download Plain textCitation fields reflect the indexed metadata. Check author formatting and publication details against the source before submission.
Record provenance
Indexed record: W4396708282. Matched to Scopus author 55279534900.
Scopus record ↗Metadata retrieved 2026-09-20. Topic labels are navigation aids derived from title and abstract text.