Reliability of the Modified Four Square Step Test (mFSST) in patients with primary total knee arthroplasty.
This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.
DOI: 10.1080/09593985.2019.1633713
Bibliographic record from the original reports
Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.
Unver B, Sevik K, Yarar HA, Unver F, Karatosun V. Reliability of the Modified Four Square Step Test (mFSST) in patients with primary total knee arthroplasty. Physiotherapy theory and practice. 2021;37(4):535-539. DOI 10.1080/09593985.2019.1633713 Source examined: Abstract verified in official PubMed; detailed protocol unavailable.
Conditions: COND-TKA Total knee arthroplasty
Scoped audit evidence
These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.
Total knee arthroplasty
- access status: public_primary_body_read
28 participants at least6months after TKA, same-day1hour repeat, practice then best of two, ICC(2,1).973. Abstract SEM/SRD.80/2.24 versus Table2 and Discussion1.11/3.10. Report does not deploy these values.
Source locator: Author-uploaded 2019 online-first PDF text: Methods pp2–3; Table2 p3; Discussion p4
Limitations: Complete primary text read through author-uploaded PDF rendering. Final issue-version identity or corrected table not independently resolved; visual table image not retrieved. Article access does not prove every table/figure/supplement was examined. Use the claim ledger and explicit source locators; do not count this inventory as a complete assertion-level audit.
Linked audit findings
Reports citing this source
- Balance assessment and prognosis after total knee arthroplasty · reference 10 · original reference
Update record
- 2026-10-03: Created from the supplied reports and final scoped audit. New evidence should be appended with source version, access date, exact locator and affected report links.
Updating the wiki · Evidence and status guide