TKA-U02 · source internal conflict
Classification and audit outcome: source internal conflict; supported.
Finding
Both pairs are printed in the same original; no evidence identifies the intended corrected pair.28 primary TKA participants were at least6months postoperative; retest was same day1hour apart.
Current amendment or qualification
Retain separate-protocol caution and add source warning if detailed values are introduced: abstract SEM/SRD.80/2.24s differs from Table2 and Discussion1.11/3.10s.
Integration note: Retain separate protocol; do not deploy either error threshold as resolved.
Evidence and provenance
Author-uploaded2019 online-first article, abstract; Table2p3; Discussionp4
- Original source
- Reliability of the Modified Four Square Step Test (mFSST) in patients with primary total knee arthroplasty. · Original source
Affected reports
Original audit locator(s): P0093; Reference11
Audit corrections describe the report only where that classification is explicit. A disagreement within a study, missing protocol, statistical query, access upgrade or optional addition is not silently converted into a report error or a new clinical threshold.