Bower Kelly J, McGinley Jennifer L, Miller Kimberly J, Clark Ross A. Instrumented static and dynamic balance assessment after stroke using Wii Balance Boards: reliability and association with clinical tests. PloS one. 2014;9(12):e115282. DOI 10.1371/journal.pone.0115282

This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.

DOI: 10.1371/journal.pone.0115282

Bibliographic record from the original reports

Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.

Bower Kelly J, McGinley Jennifer L, Miller Kimberly J, Clark Ross A. Instrumented static and dynamic balance assessment after stroke using Wii Balance Boards: reliability and association with clinical tests. PloS one. 2014;9(12):e115282. DOI 10.1371/journal.pone.0115282 Source examined: Full text.

Kelly J Bower, Jennifer L McGinley, Kimberly J Miller, Ross A Clark. Instrumented static and dynamic balance assessment after stroke using Wii Balance Boards: reliability and association with clinical tests. PloS one. 2014. DOI 10.1371/journal.pone.0115282 Source examined: Full article body and tables examined via Europe PMC.

Conditions: COND-STROKE Stroke

Scoped audit evidence

These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.

Stroke

30 outpatients,>3 months, median 13.5 months; all independent walkers.40 Hz/12 Hz 8 th-order filter; median 3 except 1 loading trial; mean WBBtime 21 min. Table 2 reproduces COP ICC/SEM/MDC and FRMDC 6.24 cm; loading MDC 10 percentagepoints. STS n 23; force ICC.90/MDC 6.14%BW, RFDICC.94/MDC 84.53%BW/s, ratio MDC.12/.19. S 1 confirmsheels 17 cm, toeout 14°, knee 75°, ankle 5–10°, self-paced 3 rises, noarms; support/assistance invalidatestrial.

Source locator: Methods; Results; Table 2; Table 3; File S 1 protocol panels

Limitations: Supplementary protocol directly checked. Published STS peak-force difference sign and asymmetry MDC percentage appear inconsistent, but the report does not reproduce those fields.