Achieving normative quadriceps strength after total knee arthroplasty : associations with satisfaction, function, and a predictive nomogram.
This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.
DOI: 10.1302/0301-620x.108b4.bjj-2025-0859.r2
Bibliographic record from the original reports
Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.
Hiyama Y, Sawa R, Yokoyama M, Ohtera S, Wada O, Mizuno K. Achieving normative quadriceps strength after total knee arthroplasty : associations with satisfaction, function, and a predictive nomogram. The bone & joint journal. 2026;108-B(4):469-477. DOI 10.1302/0301-620x.108b4.bjj-2025-0859.r2 Source examined: Complete publisher PDF; p 473 numerical results visually checked; supplement not retrieved.
Conditions: COND-TKA Total knee arthroplasty
Scoped audit evidence
These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.
Total knee arthroplasty
- access status: public_primary_body_read
1,341 patients/1,475 knees;564 development+911 temporal validation;120 reference adults 240 knees.90-degree stabilized torque protocol,3-second best-of 2;0.97/1.17 Nm/kg thresholds. AUC.888(.847–.931),intercept−.107,slope.885,Brier.135 and outcome-time contralateral input visually confirmed. Supplement not retrieved.
Source locator: Publisher PDF pp 470–475; p 473 visually inspected
Limitations: Body extraction may omit images, equations or supplements. Metadata publication year may represent online-first date, not issue year. Article access does not prove every table/figure/supplement was examined. Use the claim ledger and explicit source locators; do not count this inventory as a complete assertion-level audit.
Reports citing this source
- Strength power and rapid force assessment after total knee arthroplasty · reference 16 · original reference
Update record
- 2026-10-03: Created from the supplied reports and final scoped audit. New evidence should be appended with source version, access date, exact locator and affected report links.