← Clinical Evidence

SRC-bf41d6fcee0d Maribo T 2009

Evidence source and scope

21. Maribo T, Iversen E, Andersen NT, Stengaard-Pedersen K, Schiøttz-Christensen B. Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients. International Musculoskeletal Medicine. 2009;31(4):172-177. DOI 10.1179/175361409x12472218841040

This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.

DOI: 10.1179/175361409x12472218841040

Bibliographic record from the original reports

Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.

Maribo T, Iversen E, Andersen NT, Stengaard-Pedersen K, Schiøttz-Christensen B. Intra-observer and interobserver reliability of One Leg Stand Test as a measure of postural balance in low back pain patients. International Musculoskeletal Medicine. 2009;31(4):172-177. DOI 10.1179/175361409x12472218841040 Source examined: Original publisher PDF inspected independently including Tables 1 and 2 on printed pages 174–175; direct source-specific clinical error estimates.

Conditions: COND-LBP Low back pain

Scoped audit evidence

These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.

Low back pain

Source locator: PDF printed 173–176; Tables 1–2

Limitations: Printed SEM definition is ambiguous about the SD used; table magnitudes agree with difference-score error.

Low back pain

48 enrolled; EC intra n 20/inter n 27,20-minute retest; SEM 2.48/1.42, MDC 6.88/3.95 and ICC .86/.91 match. Best trial then poorer leg, EO ceiling and outlier influence support cautions.

Source locator: PDF printed 173–176; Tables 1–2

Limitations: Printed SEM definition is ambiguous about the SD used; table magnitudes agree with difference-score error.