← Clinical Evidence

SRC-7793ba556d88 Bravi M 2020

Evidence source and scope

Concurrent validity and inter trial reliability of a single inertial measurement unit for spatial-temporal gait parameter analysis in patients with recent total hip or total knee arthroplasty.

This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.

DOI: 10.1016/j.gaitpost.2019.12.014

Bibliographic record from the original reports

Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.

Bravi M, Gallotta E, Morrone M, Maselli M, Santacaterina F, Toglia R, et al. Concurrent validity and inter trial reliability of a single inertial measurement unit for spatial-temporal gait parameter analysis in patients with recent total hip or total knee arthroplasty. Gait & posture. 2020;76:175-181. DOI 10.1016/j.gaitpost.2019.12.014 Source examined: Abstract verified; full article unavailable.

Bravi M, Gallotta E, Morrone M, Maselli M, Santacaterina F, Toglia R, et al. Concurrent validity and inter trial reliability of a single inertial measurement unit for spatial-temporal gait parameter analysis in patients with recent total hip or total knee arthroplasty. Gait & posture. 2020;76:175-181. DOI 10.1016/j.gaitpost.2019.12.014 Source examined: Original abstract only; full article not retrieved.

Conditions: COND-THA Total hip arthroplasty, COND-TKA Total knee arthroplasty

Scoped audit evidence

These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.

Total knee arthroplasty

Only abstract-level claims can be checked; full methods, original tables, figures and supplements remain unverified.

Source locator: Official PubMed abstract

Limitations: Body extraction may omit images, equations or supplements. Metadata publication year may represent online-first date, not issue year. Article access does not prove every table/figure/supplement was examined. Use the claim ledger and explicit source locators; do not count this inventory as a complete assertion-level audit.

Total hip arthroplasty

20 recent THA/TKA patients with crutches, 10 controls; single lower-trunk IMU versus optical reference, five walks. Patient correlations .704–.986 general spatiotemporal versus .077–.464 gait phases.

Source locator: Pub Med PMID31862666 Methods/Results

Limitations: Correlation is not interchangeability; mixed surgery and crutches limit transfer. Exact full protocol unavailable. No usable body obtained through checked lawful routes; not proof that no lawful copy exists.

Reports citing this source

Update record

Updating the wiki · Evidence and status guide