Validity and reliability of the modified four square step test in total HIP arthroplasty.

This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.

DOI: 10.1016/j.jbmt.2024.04.028

Bibliographic record from the original reports

Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.

Horata ET, Eken F, Yesil M, Ozcan O. Validity and reliability of the modified four square step test in total HIP arthroplasty. Journal of bodywork and movement therapies. 2024;40:345-349. DOI 10.1016/j.jbmt.2024.04.028 Source examined: Original abstract only; full article not retrieved.

Conditions: COND-THA Total hip arthroplasty

Scoped audit evidence

These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.

Total hip arthroplasty

29 patients, mean age 56.86; cross-sectional mFSST tape version; ICC .925, SEM1.56 s, MDC95 4.32 s; rTUG .881, BBS−.718. Report values and distinction from cane obstacles match.

Source locator: Pub Med PMID39593608 Methods/Results

Limitations: Postoperative stage, retake structure, between-day interval and exact protocol unverified; no MIC/future-fall validation. No usable body obtained through checked lawful routes; not proof that no lawful copy exists.