Monitoring Gait Recovery After Total Knee Arthroplasty Using Wearable Sensors: Responsiveness of Gait Accelerations.
This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.
DOI: 10.1002/jor.70058
Bibliographic record from the original reports
Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.
Ghaffari A, Clasen PD, Kappel A, Rasmussen J, Gurchiek RD, Kold S, et al. Monitoring Gait Recovery After Total Knee Arthroplasty Using Wearable Sensors: Responsiveness of Gait Accelerations. Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 2025;43(12):2165-2177. DOI 10.1002/jor.70058 Source examined: Complete original article; exploratory wearable study.
Conditions: COND-TKA Total knee arthroplasty
Scoped audit evidence
These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.
Total knee arthroplasty
- access status: full_body_retrieved
31 selected unaided participants;2 weeks preop to 90 days;thighsensor;repeated observation and LASSO classification contemporaneous weekly response. Correctly not future disability forecast.
Source locator: Methods s 5,s 9,s 21; Results s 24,s 36
Limitations: Body extraction may omit images, equations or supplements. Metadata publication year may represent online-first date, not issue year. Article access does not prove every table/figure/supplement was examined. Use the claim ledger and explicit source locators; do not count this inventory as a complete assertion-level audit.
Reports citing this source
- Gait assessment and prognosis after total knee arthroplasty · reference 21 · original reference
Update record
- 2026-10-03: Created from the supplied reports and final scoped audit. New evidence should be appended with source version, access date, exact locator and affected report links.
Updating the wiki · Evidence and status guide