The test-retest reliability and concurrent validity of the five times sit to stand test and step test in older adults with total hip arthroplasty.

This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.

DOI: 10.1016/j.exger.2020.111143

Bibliographic record from the original reports

Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.

Özden F, Coşkun G, Bakırhan S. The test-retest reliability and concurrent validity of the five times sit to stand test and step test in older adults with total hip arthroplasty. Experimental gerontology. 2020;142:111143. DOI 10.1016/j.exger.2020.111143 Source examined: Original abstract only; full article not retrieved.

Conditions: COND-THA Total hip arthroplasty

Scoped audit evidence

These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.

Total hip arthroplasty

32 unilateral THA; mean age 75.4.5 STS ICC .987, SEM1.05 s, MDC95 2.91 s; rHHS−.522, TUG .730. Right-step ICC .908, SEM .37, MDC1.02; left .846,.55, 1.52. Duplicated right-side validity label is present in abstract.

Source locator: Pub Med PMID33157185 Methods/Results

Limitations: No reliable relabeling as operated/nonoperated. Chair/step protocol, postoperative stage and retest interval unresolved. No usable body obtained through checked lawful routes; not proof that no lawful copy exists.