SRC-1d77ab0e8733 Mancini M 2012

Evidence source and scope

Mancini M, Salarian A, Carlson‐Kuhta P, et al. ISway: a sensitive, valid and reliable measure of postural control. Journal of NeuroEngineering and Rehabilitation. 2012. DOI 10.1186/1743-0003-9-59

This note indexes a cited or audit-added source. It may be an original study, review, guideline, form or methods reference. Treat the specific design and the evidence below as authoritative; a source note is not automatically a primary study.

DOI: 10.1186/1743-0003-9-59

Bibliographic record from the original reports

Access labels embedded in these original reference strings are historical. Current access and exact checked components are stated separately below.

Mancini M, Salarian A, Carlson‐Kuhta P, et al. ISway: a sensitive, valid and reliable measure of postural control. Journal of NeuroEngineering and Rehabilitation. 2012. DOI 10.1186/1743-0003-9-59

Conditions: COND-PD Parkinson’s disease

Scoped audit evidence

These are source- and component-level audit summaries as of 3 October 2026. Access and comparison scope can differ by report; none certifies every result or the underlying raw data.

Parkinson’s disease — balance

Balance P315/P322/P326/P356–358: distinct laboratory validation (13 untreated PD/12 controls,3x120s) and clinic reliability (17 ON PD/17controls,3x30s,30min retest with replacement) confirmed. L5,10cm heels,crossed arms in laboratory, Table3 RMS r.74 and velocity r.12; Table4 jerk ICC.86(.66–.95),RMS.83(.59–.93),median frequency.35(−.13–.70). No measurement-error SEM/MDC reported; table SEM denotes standard error of mean. Source locator: s2–8 Methods; s9 Table3; s10 Table4 Limit: Protocol transfer caveats and distinction between acceleration and CoP are supported.

Limitations: Only scoped comparisons, not whole-paper certification.

Parkinson’s disease — balance1

Balance P315/P322/P326/P356–358: distinct laboratory validation (13 untreated PD/12 controls,3x120s) and clinic reliability (17 ON PD/17controls,3x30s,30min retest with replacement) confirmed. L5,10cm heels,crossed arms in laboratory, Table3 RMS r.74 and velocity r.12; Table4 jerk ICC.86(.66–.95),RMS.83(.59–.93),median frequency.35(−.13–.70). No measurement-error SEM/MDC reported; table SEM denotes standard error of mean. Source locator: s2–8 Methods; s9 Table3; s10 Table4 Limit: Protocol transfer caveats and distinction between acceleration and CoP are supported.

Limitations: Only scoped comparisons, not whole-paper certification.