← Clinical Evidence

AUD-THA-C02

Evidence source and scope

THA-C02 · report agreement overstatement

Classification and audit outcome: report agreement overstatement; supported.

Finding

Walking correlations were high, but figures show nonzero biases and dispersed agreement limits. Figure units require reconciliation. Blanket very close agreement is insufficiently supported.

Current amendment or qualification

Same-trial supervised comparisons showed high correlations. Chair-rise counts agreed exactly in the observed sample. Walking measurements showed systematic offsets and nonzero limits of agreement in Figures 5–7; their plotted units and clinical tolerances require clarification before claiming interchangeability.

Integration note: Qualify walking agreement by output; do not infer clinical interchangeability from correlations.

Remaining limitation: Plotted walking units remain unresolved; no conversions performed.

Evidence and provenance

Affected reports

Original audit locator(s): P127; P143; P281; P282; P283

Audit corrections describe the report only where that classification is explicit. A disagreement within a study, missing protocol, statistical query, access upgrade or optional addition is not silently converted into a report error or a new clinical threshold.

Audit register · Unresolved evidence queue

Linked knowledge pages

Located in this vault

Mapping status: exact. An exact location match is not an additional empirical verification.