Type: recommended precision addition; core reported numbers correct.
Finding
Rose’s error estimate is for the mean of two trials per set; reporting only average per-rise event duration omits an additional aggregation step. The MDC formula is 95%.
Current wording or annotation
Within-home redon/retest of the mean of two trials had ICC 0.89 and MDC95 about 0.25 seconds for average detected rise duration.
Located in this report
- P0194 · sts-B098-S03
- P0133, P0134, P0135, P0136 · sts-B061-R07
- P0345, P0346, P0347, P0348 · sts-B155-R03
Sit to stand assessment and prognosis in knee osteoarthritis · Audit register · KOA sit to stand evidence boundaries