Type: association versus agreement terminology.

Finding

The executive summary says weak agreement between performance and self-report, while the cited analyses test correlations/construct hypotheses, not agreement between interchangeable measurements.

Current wording or annotation

Several studies found weak associations between performance and patient-reported function.

Source: Original source

Source locator: Suwit Table 3; Tolk Table 3

Located in this report