← Clinical Evidence

AUD-KOA-C13

Evidence source and scope

KOA-C13 · report null result precision

Classification and audit outcome: report null result precision; supported.

Finding

The table’s phrase concurrent KL-grade associations does not state that the original study found no significant association/differences.

Current amendment or qualification

No significant differences in one-leg stance balance or quadriceps strength-to-body-weight ratio were found across KL grades in these selected independently ambulant older men.

Integration note: State null finding with selected ambulant older-male sample; absence of significance is not equivalence.

Evidence and provenance

Primary abstract Results/Conclusion and full body. This clarifies a null finding rather than reversing the report’s population caveat.

Affected reports

Original audit locator(s): block 105

Audit corrections describe the report only where that classification is explicit. A disagreement within a study, missing protocol, statistical query, access upgrade or optional addition is not silently converted into a report error or a new clinical threshold.

Audit register · Unresolved evidence queue

Located in this vault

Mapping status: exact. An exact location match is not an additional empirical verification.