KOA-C04 · report protocol precision
Classification and audit outcome: report protocol precision; supported.
Finding
The report calls Wegner testing barefoot; the Methods specify removal of shoes, without stating whether socks were removed.
Current amendment or qualification
Treadmill testing with shoes removed; sock status was not specified.
Integration note: Replace with shoes removed; do not infer sock status.
Evidence and provenance
Original Methods, capture protocol. Avoid inventing a more precise footwear condition.
- Gait assessment using a 2D video-based pose estimation app in comparison to a markerless motion capture system in subjects with osteoarthritis of the knee - a pilot study. · Original source
Affected reports
Original audit locator(s): block 124
Audit corrections describe the report only where that classification is explicit. A disagreement within a study, missing protocol, statistical query, access upgrade or optional addition is not silently converted into a report error or a new clinical threshold.
Audit register · Unresolved evidence queue
Linked knowledge pages
- COND-KOA Knee osteoarthritis
- TEST-MARKERLESS Markerless and video gait analysis
Located in this vault
Mapping status: exact. An exact location match is not an additional empirical verification.